Johns Manville Roofing System

Commercial Roofing

CONTACT INFO
717 17th St. P. O. Box 5108
Denver, CO 80217-5108
Toll Free: 800-654-3103
Phone: 303-978-2000
Continuing Education Logo
Request for information Johns Manville Roofing System Contact Us / RFI

Johns Manville Roofing System CAD Details Search using keywords: stone wall bank protection

E-FW-B4 Base Tie-In - Fastener & Plate On Wall

3E-FW-B8 Base Tie In (Polymer Batten Strip) on Wall 6 inch Sealing Strip

3E-DV-05 Through Wall Welded Scupper Sleeve

3E-DV-05I Through Wall Welded Scupper Sleeve

3E-DV-06 Wall Overflow Welded Scupper Sleeve

3E-DV-06I Wall Overflow Welded Scupper Sleeve

E-DV-03 Through-Wall Scupper

E-DV-04 Through-Wall Scupper

E-DV-04I Through-Wall Scupper

E-DV-06 Low Wall Primary Scupper Flashing

3E-EJ-01 EJ Roof to Wall with RTS Strip

3E-EJ-02 EJ Roof to Wall with 6 inch Sealing Strip

3E-EJ-05 Expand-O-Flash Curb to Wall EJ Cover (RTS)

3E-EJ-06 Expand-O-Flash Curb to Wall EJ 6 inch Sealing Strip

E-EJ-01 Expansion Joint - Roof To Wall

E-EJ-03 Expand-O-Flash Curb To Wall Expansion Joint Cover- Style CF/EJ

E-EJ-05 Expand-O-Flash Roof To Wall - Style EJ

E-EJ-07 Expand-O-Flash Curb To Wall Expansion Joint Cover - Style CF/EJ

E-EJ-09 Expand-O-Flash Curb To Wall - Style EJ/WC

E-EJ-12 EJ Roof to Wall with 6 inch Sealing Strip

E-EJ-13 EJ Roof to Wall with 6 inch Seam Tape

3E-FC-14 Inside Corner with Separate Wall Flashing

3E-FC-14I Inside Corner with Separate Wall Flashing Installation

E-FC-13 EPDM Inside Corner with Seam Tape and Vertical Wall Fastening

E-FC-14 EPDM Flashing Wall with Term Bar and Corner Coping

E-FW-M1 EPDM Base & Wall Flashing with Coping Master Detail

E-FW-M1I EPDM Base & Wall Flashing with Coping Isometric View Master Detail

3E-MS-03 Lap Splice Under Wall Flashing with Sealing Strip

3E-MS-06 Lap Splice at Wall Flashing with Sealing Strip

E-PT-01 Support-Light

E-PT-02 Support-Medium

E-PT-03 Support-Heavy

E-PT-04 Walkway-Concrete Paver

E-PT-05 EPDM Peel & Stick Walkpads Over EPDM Membrane

E-PT-06 Ballasted EPDM

E-PT-07 Lightning Rod-Wall Mount

E-PT-08 Lightning Rod-Roof Mount

E-PT-09 JM ENRGY Anchor - EPDM

E-PT-10 Hurricane Peel Stop Anchor Bar

3E-FW-I3 Intermediate Termination Below Wall Cladding

E-FW-I4 EPDM Intermediate Termination with Through-Wall Counter Flashing

E-FW-I5 EPDM Intermediate Termination Below Wall Cladding

SPL-EJ-02 Expansion Joint EPDM Roof to Wall

SPL-FW-02 Wall Mounted Ladder EPDM Base Flashing

SPL-FW-04 Deck Mounted Ladder EPDM Base Flashing

SPL-FW-05 Flashing Wall Optional Terminations

3E-FW-T1 Top of Wall Termination with Stone Coping

3E-FW-T2 Presto-Lock Coping Over EPDM

3E-FW-T3 Fabricated Metal Coping Over Adhered EPDM

3E-FW-T4 Presto-Tite Fascia on Sloped Parapet

3E-FW-T5 Presto-Tite Fascia on Flat Parapet

E-FW-T1 Fabricated Metal Coping Over Adhered EPDM

E-FW-T4 Perma-Tite Continuous Cleat Coping System Over EPDM

VB-1 (ALT) JM Vapor Barrier SA - Wall Base Detail - Alt

VB-1 JM Vapor Barrier SA - Wall Base Detail

VB-1 (ALT) JM Vapor Barrier SAR - Wall Base

VB-1 JM Vapor Barrier SAR - Wall Base

P-FW-B2 Base Tie-In - Fastener & Plate - On Wall

P-FW-B6I PVC Fleece backed in RSUA Base & Wall Flashing

P-FW-B7I - PVC Fleece Backed in Two Part UIA Base & Wall Flashing Spatter

PH-FW-B3 Base Tie-In - Fastener & Plate - On Wall

PH-FW-M1 PVC Hybrid Base and Wall Flashing With Coping

PH-FW-M1I PVC Hybrid Base & Wall Flashing with Coping - Isometric View

P-FW-I2 PVC Detail Strip Wall Flashing Attachment with Fastener & Plate

P-FW-I9 PVC Intermediate Termination with Through-Wall Counterflashing

P-FW-I11 PVC Intermediate Termination Below Wall Cladding

P-DV-03 Through-wall Scupper

P-DV-03I Through-wall Scupper

P-DV-05 Low-Wall Primary Scupper Flashing

P-EJ-01 Expansion Joint-Roof To Wall

P-EJ-04 Expand-O-Flash RoofTo Wall - Style EJ

P-EJ-06 Expand-O-Flash Curb To Wall Expansion Joint Cover-Style CF/EJ

P-EJ-07 Expand-O-Flash Curb To Wall Expansion Joint Cover-Style PVC EJ/WC

P-FC-06 Flashing Wall With Term Bar and Corner Coping

P-FW-M1 PVC Base & Wall Flashing with Coping Master Detail

P-FW-M1I PVC Base & Wall Flashing with Coping Isometric View Master Detail

P-FW-M3I PVC Rhinobond Continuous Wall Flashing Isometric View Master Detail

P-FW-M4I PVC Rhinobond Wall Flashing Isometric View Master Detail

P-PT-01 Support-Light

P-PT-02 Support-Medium

P-PT-03 Support-Heavy

P-PT-04 Walkway-Concrete Paver

P-PT-05 PVC Walkpads Over Adhered PVC Membrane

P-PT-06 PVC Walkpad Fleece Backed System Fully Adhered

P-PT-07 PVC Walkpad Over Mechanically Fastened PVC Membrane

P-PT-08 Lightning Rod-Wall Mount

P-PT-09 Lightning Rod-Roof Mount

P-PT-10 Grease Trap

P-PT-11 JM ENRGY ANCHOR - PVC

P-PT-12 JM PVC Safety Strip Over PVC Membrane

P-PT-13 Hurricane Peel Stop Anchor Bar

SPL-EJ-01 Expansion Joint TPO or PVC Roof to Wall

SPL-FW-01 Wall Mounted Ladder TPO or PVC Base Flashing

SPL-FW-05 Flashing Wall Optional Terminations

SPL-FW-03 Deck Mounted Ladder TPO or PVC Base Flashing

P-FW-T1 Fabricated Metal Coping Over Adhered PVC

P-FW-T2 Presto Lock Coping System Over PVC

P-FW-T3 Presto-Tite Fascia System On Sloped Parapet

P-FW-T4 Perma-Tite Continuous Cleat Coping System Over PVC

VB-1 JM Vapor Barrier SA - Wall Base Detail

VB-1 (ALT) JM Vapor Barrier SA - Wall Base Detail - Alt

VB-1 JM Vapor Barrier SAR - Wall Base

VB-1 (ALT) JM Vapor Barrier SAR - Wall Base

BIT-1 (NLB) Base Flashing for Non Load Brng Wall-Curb to Wall EJ

BIT-5 Base Flashing for Non Load Bearing Wall & Metal EJ

BIT-16 Roof Penetration Pan

BIT-17 Lightning Rod on Roof Surface

BIT-PT-01 Bituminous Light Support

BIT-PT-02 Bituminous Medium Support

BIT-PT-03 Bituminous Heavy Support

BIT-PT-04 DynaTred Traffic Pads with Pavers

BIT-PT-05 DynaTred Traffic Pads

BIT-1 (LB) Base Flashing for Load Brng Wall with Counterflashing

BIT-2 (WL) Base Flashing for Wall less than 24 inches

BIT-3 (WH) Base Flashing for Wall more than 24 inches with Coping

BIT-3 (WL) Base Flashing for Wall less than 24 inches with Coping

BIT-6 (TH) Base Flashing for Wall more than 24 inches with Coping

BIT-6 (TL) Base Flashing for Wall less than 24 inches with Coping

BIT-15 (E) EPDM Wall Covering with BUR Base Flashing

BIT-15 (E) Alt-EPDM Wall Covering with BUR Base Flashing

BIT-15 (P) PVC Wall Covering with BUR Base Flashing

BIT-15 (T) TPO Wall Covering with BUR Base Flashing

DFE-1 (NLB) Curb to Wall Expansion Joint

DFE-17 Lightning Rod, Surface Mount

DFE-16 Penetration Pocket

DFE-10 FP-10 One Way® Roof Vent

DFE-9 Plumbing, Lead

DFE-23 Vent Stack (Warm)

DFE-18 JM Energy Anchor - SBS Adhered

DFE-1 (LB) Masonry Wall with Counter Flashing

DFE-2 (LB) Two Ply Base Flashing for LB Masonry Wall Counter Flashing

DFE-2 (PT) Perma Tite Coping

DFE-2 Base Flashing with Surface Mounted Counter Flashing

DFE-3 (WH) Wood Wall > 24" with Coping

DFE-3 (WL) Wood Wall < 24" with Coping

DFE-6 (TH) Masonry Wall > 24" with Coping

DFE-6 (TL) Masonry Wall < 24" with Coping

DFE-15 (ALT) TPO Wall Covering with Bituminous Base Flashing (Alternate)

DFE-15 (E) EPDM Wall Covering with Bituminous Base Flashing

DFE-15 (P) PVC Wall Covering With Bit Base Flashing

DFE-15 (T) TPO Wall Covering with Bituminous Base Flashing

DFE-20 (WH) Gypsum Wall on Metal Studs > 24" w/Coping

DFE-20 (WL) Gypsum Wall on Metal Studs < 24" w/Coping

DFE-24 Base Flashing for Venting Lightweight Concrete

DGE-17 Lightning Rod, Surface Mount

DGE-16 Penetration Pocket

DGE-1 (LB) Masonry With Nailing Facilities

DGE-2 (LB) Two Ply Base Flashing for LB Masonry Wall Counter Flashing

DGE-2 Base Flashing with Surface Mounted Counter Flashing

DGE-3 (HW) Base Flashing for Wood Wall +24 Inches with Coping

DGE-3 (LW) Base Flashing for Wood Wall -24 Inches with Coping

DGE-6 (TH) Tilt-Up, High

DGE-6 (TL) Tilt-Up, Low

DGE-15 Single Ply Wall Covering with BIT Base Flashing

HW-1 (NLB) Base Flashing Curb to Wall EJ

HW-16 Penetration Pocket

HW-17 Lightning Rod on Roof Surface

HW-18 JM Energy Anchor

HW-1 (LB) Masonry Wall w/ Counterflashing

HW- 2 (PT) Perma Tite Coping

HW-3 (WH) Wood Wall >24” with Coping

HW-3 (WL) Wood Wall <24” with Coping

HW-6 (TH) Masonry Wall >24” with Coping

HW-6 (TL) Masonry Wall <24” with Coping

HW- 6 (TL) ALT - Base Flashing For Masonry Wall

HW-15 (E) EPDM Wall Covering with Bituminous Base Flashing

HW-15 (T) TPO Wall Covering with Bituminous Base Flashing

HW-15 (T-ALT) TPO Wall Covering with Bituminous Base Flashing

HW-20 (WH) Gypsum Wall on Metal Studs >24” w/ Coping

HW-20 (WL) Gypsum Wall on Metal Studs <24” w/ Coping

HW-24 Venting Lightweight Concrete

HW-25 (LB) Optional Two-Ply Base Flashing for Load-Bearing Masonry Wall w/ Counterflashing

CBE-17 Lightning Rod, Surface Mount

CBE-16 Penetration Pocket

CBE-1 (LB) Masonry With Nailing Facilities

CBE-2 (LB) Two Ply Base Flashing for LB Masonry for LB Masonry Wall Counter Flashing

CBE-2 Base Flashing with Surface Mounted Counter Flashing

CBE-3 (HW) BASE FLASHING FOR WOOD WALL +24 INCHES WITH COPING

CBE-3 (LW) BASE FLASHING FOR WOOD WALL -24 INCHES WITH COPING

CBE-6 (TH) BASE FLASHING +24 INCHES WITH COPING ALT

CBE-6 (TL) BASE FLASHING FOR MASONRY WALL -24 INCHES WITH COPING

CBE-15 SINGLE PLY WALL COVERING WITH BIT BASE FLASHING

PMF-7 PermaFlash® Through-Wall Scupper Detail

PMF-7S PermaFlash® Through-Wall Scupper Scrim Detail

PMF-1 PermaFlash® I-Beam Detail

PMF-11 PermaFlash® Square Metal Tube Detail

PMF-11S PermaFlash® Square Metal Tube Scrim Detail

PMF-1S PermaFlash® I-Beam Scrim Detail

PMF-2 PermaFlash® Angle Iron Detail

PMF-2S PermaFlash® Angle Iron Scrim Detail

VB-1 JM Vapor Barrier SA - Wall Base Detail

VB-1 (ALT) JM Vapor Barrier SA - Wall Base Detail (Alt)

VB-1 JM Vapor Barrier SAR - Wall Base

VB-1 JM Vapor Barrier SAR - Wall Base (ALT)

SPL-EJ-01 Expansion Joint TPO or PVC Roof to Wall

SPL-FW-01 Wall Mounted Ladder TPO or PVC Base Flashing

SPL-FW-03 Deck Mounted Ladder TPO or PVC Base Flashing

SPL-FW-05 Flashing Wall Optional Terminations

T-FW-B10 TPO Self Adhered Base Tie-In (Fastener & Plate) On Wall

T-FW-B13I TPO Fleece backed in RSUA Base and Wall Flashing

T-FW-B14I TPO Fleece Backed Base and Wall in Two Part UIA Spatter

T-FW-B4 Base Tie-In Fastener & Plate on Wall

T-FW-B7 Base Tie-in Knee Wall Brace 2/12 Slope

T-DV-03 Through-wall Scupper

T-DV-03I Through-wall Scupper

T-DV-05 Low-Wall Primary Scupper Flashing

T-EJ-01 Expansion Joint-Roof To Wall

T-EJ-04 Expand-O-Flash Roof To Wall-Style EJ

T-EJ-06 Expand-O-Flash Curb To Wall Expansion Joint Cover-Style CF/EJ

T-EJ-07 Expand-O-Flash Curb to Wall (Style TPO EJ-WC)

T-EJ-09 Expand-O-Flash Curb to Wall Expansion Joint Cover-Style CF/EJ

T-FC-06 TPO Flashing Wall with Term Bar and Corner Coping

T-FW-I11 TPO Intermediate Termination Below Wall Cladding

T-FW-I2 TPO Cover Strip Wall Flashing Attachment with Fastener & Plate

T-FW-I9 TPO Intermediate Termination with Through-Wall Counterflashing

T-FW-M1 TPO Base & Wall Flashing with Coping Master Detail

T-FW-M1I TPO Base & Wall Flashing with Coping Isometric View Master Detail

T-FW-M3I TPO Self Adhered Base & Wall Flashing with Coping Isometric View

T-FW-M4I TPO Base and Wall Flashing with Coping ISO View

T-FW-M5I TPO RhinoBond Wall Flashing ISOmetric View

T-FW-M6I TPO Rhinobond Wall Flashing ISO Metric View

T-FW-M7I TPO Base and Wall Flashing 10 FT Max with Coping

T-PT-01 Support-Light

T-PT-02 Support-Medium

T-PT-03 Support-Heavy

T-PT-04 Walkway-Concrete Paver

T-PT-05 TPO Walkpads Over Adhered TPO Membrane

T-PT-06 TPO Walkpad Fleece Backed System Fully Adhered

T-PT-07 TPO Walkpad Over Mechanically Fastened TPO Membrane

T-PT-08 Lightning Rod-Wall Mount

T-PT-09 Lightning Rod-Roof Mount

T-PT-10 Grease Trap

T-PT-11 JM Single Ply Safety Strip Over TPO Membrane

T-PT-12 JM ENRGY Anchor - TPO

T-PT-13 Hurricane Peel Stop Anchor Bar

T-FW-B10 TPO Self-Adhered Base Tie-In (Fastener & Plate) on Wall

T-FW-M3I Self-Adhered TPO Base & Wall Flashing with Coping ISO View

T-FW-M8I TPO Self-Adhered Continuous Wall Flashing

T-FW- T1 Fabricated Metal Coping Over Adhered TPO

T-FW- T2 Presto Lock Coping System Over TPO

T-FW- T3 Presto-Tite Fascia System On Sloped Parapet

T-FW- T4 Perma-Tite Continuous Cleat Coping System Over TPO

T-FW- T5 Top of Wall Termination with Stone Coping

TWE-DV-03 - Through-Wall Scupper with JM White EPDM

TWE-FW-01 - TPO End Wall Transistion with JM White EPDM

TH-FW-B3 - Base Tie In (Fastener & Plate) On Wall

TH-FW-M1 - TPO Hybrid Base & Wall Flashing with Coping Master

TH-FW-M1I - Hybrid Base & Wall Flashing with Coping Isometric View

VB-1 (ALT) JM Vapor Barrier SA - Wall Base Detail - Alt

VB-1 JM Vapor Barrier SA - Wall Base Detail

VB-1 (ALT) JM Vapor Barrier SAR - Wall Base

VB-1 JM Vapor Barrier SAR - Wall Base